Installation
Important:
This thermostat must be installed according to all national
and local electrical codes. The installation must be performed by quali-
fied personnel.
Locating the floor temperature sensor
The floor temperature sensor is installed under the floor surface. See the
QuickNet System Installation Manual (H57704),
Section 6, for more
details.
If required, the sensor cable can be extended to about 300 ft (91 m).
Wiring the thermostat
WARNING: TURN OFF THE POWER TO THE CIRCUIT
AT THE MAIN POWER PANEL TO AVOID ELECTRIC SHOCK.
1. Connect power to the thermostat’s line terminals marked “L1 (L)”
and “L2 (N)”.
2. Connect the floor warming cold lead to the load terminals marked
“Load 16A Max”.
3. Connect the floor temperature sensor to the screw-less terminals
marked “Sensor”. Push on the terminal spring with a screwdriver and
insert the wires.
Mounting the thermostat in the electrical box
1. Use a screwdriver to remove the cover.
2. Mount the thermostat in the wall socket and re-attached the cover.
Thermostat Controls and Display Symbols
The following figure shows the thermostat controls:
The following figure shows the symbols that appear in the display
window while you are programming:
Clock function
Manual mode
Time and
temperature
Day number
4-event symbol:
Wake
Night
Out
Home
% switch-on time
Heating on
Reset
GFCI
Test
R
Reset button
Red light indicating
ground-fault
Test button
Pin button for
adjusting clock
Adjustment up
OK - accept
Digital
display
Adjustment down
Reset button for
factory settings
L
1
(L
)
L
2
(N
)
2
4
0
/(1
2
0
)V
A
C
1
6
A
M
a
x
.
Q
uickStat
®
G
FCI Class A
LINE
LOAD
S
E
N
S
O
R
C
A
U
T
IO
N
:
High Voltage - Disconnect
power supply before servicing
DUAL VOLTAGE 50/60 Hz
3840W/240VAC (16A)
1920W/2120VAC (16A)
L1 (L)
L2 (N)
240/(120)VAC
16A
Max.
QuickStat
®
GFCI Class A
LINE
LOAD
SENSOR
1/4" (6 mm)
Strip length
Line (black)
Neutral (white)
Cold lead
Cold lead
QuickStat Installation & Operation Manual
2
Vista de página 1
1 2 3 4 5 6 7 ... 11 12

Comentários a estes Manuais

Sem comentários