Programming
The QuickStat-TC comes with a pre-programmed default
schedule. The schedule consists of 4 periods per day which
represents a typical week day.
Period Description Associated temperature setting
Wake-up
Away from home
Return home
Sleep
Default Programming
The following shows the pre-programmed default schedule in the
QuickStat-TC.
Period Setting
MO TU WE TH FR SA SU
6:00A 6:00A 6:00A 6:00A 6:00A 6:00A 6:00A
8:30A 8:30A 8:30A 8:30A 8:30A --:-- --:--
5:00P 5:00P 5:00P 5:00P 5:00P --:-- --:--
11:00P 11:00P 11:00P 11:00P 11:00P 11:00P 11:00P
The Comfort ( ) temperature is used in periods 1 and 3 and
the Economy (
) temperature is used in periods 2 and 4. For
example, when the period changes from 1 to 2, the setpoint
automatically changes from Comfort (
) temperature to
Economy (
) temperature.
Preset Temperatures
The QuickStat-TC comes with 3 preset temperatures shown
as Comfort (
) temperature, Economy ( ) temperature
and Vacation (
) temperature. The following table shows the
intended use and the default setting of each preset temperature.
Icon Intended use
A/AF
modes F mode
Comfort
(when at home)
70°F
(21°C)
82°F
(28°C)
Economy
(when asleep or away from home)
63°F
(17°C)
68°F
(20°C)
Vacation
(during prolonged absence)
50°F
(10°C)
50°F
(10°C)
Users can also change a preset temperature by:
1. Set the desired temperature using the
buttons.
2, Press and hold the corresponding preset button (
, , or
) until the corresponding icon is displayed.
Floor Temperature Limit (AF Mode Only)
The default temperature limits are 41°F to 82°F (5°C to 28°C).
Important: If your system is installed underneath laminate
or engineered wood flooring, you MUST use AF mode with the
default settings. Note the factory default is AF mode.
Modifying the Schedule Programming
The user can change the programming to better meet their
lifestyle. To do so:
1. Press Pgm to access the programming mode. Period 1 will be
displayed.
2. Press Day to select the day to program for the selected peri-
od. To select the entire week, press and hold the Day button
for 3 seconds until all days are selected.
3. Press Hour and Min to set the start time of the selected
period, or press Clear if you want to skip the period (--:-- is
displayed).
Note: If you wish to use only 2 periods, set periods “1 and
4” or periods “2 and 3”. Early Start will not work if you set
periods “1 and 2” or periods “3 and 4”.
4. Press Pgm to select another period, or press Day to select
another day. They repeat step 3. Repeat steps 3 & 4 until pro-
gramming is complete.
5. Press Mode/Ret to exit the programming mode.
Operating Modes
The QuickStat-TC has three operating modes:
Automatic Mode
In this mode, the QuickStat-TC follows the programmed schedule.
To place the QuickStat-TC in this mode:
1. Press the Mode/Ret button until the
icon appears on the
display.
2. To disable Automatic mode, press the Mode/Ret button to
change the mode to Manual mode
.
Temporary Manual Override (in Automatic Mode )
Users can temporarily override the scheduled programming of the
QuickStat-TC. The new temperature setpoint will be used until the
beginning of the next period. To temporarily override the
QuickStat-TC:
1. Press the
, or button, while the thermostat is in
the Automatic mode, to the new desired setpoint. Once the
new setpoint is accepted, the icon will begin to flash.
2. To cancel the temporary override, press the Mode/Ret button.
Manual Mode
In this mode, the programmed schedule is not used and the
setpoint temperature must be set manually. To place the
QuickStat-TC in this mode:
1. Press the Mode/Ret button until the
icon appears on the
display.
2. Set the temperature using the
, or button.
3. To disable Manual mode, press the Mode/Ret button to
change the mode to Automatic mode
.